Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 748
Filter
1.
Desalination and Water Treatment ; 288:140-150, 2023.
Article in English | Web of Science | ID: covidwho-20244861

ABSTRACT

Like all public utility, swimming pools had been treated with special procedures during the COVID19 pandemic. In addition to the basic rules (social distance + hand disinfection + masks), applicable to all citizens, the managers of swimming pools were obliged to reduce the number of swimmers and to increase the effects of water treatment. Monitoring, control and rapid response to unfavourable changes in the quality of swimming pool water are the basis for minimizing the risk of disease transmission or exposure of bathers to pathogens. The main purpose of this work is to analyse and compare the quality of swimming pool water in a municipal outdoor swimming pool complex, before (2018-2019) and during the COVID-19 pandemic (2020-2021). Water samples taken from a paddling pool for children (CP), a recreational pool (RP), and a sports pool (SP) were analysed. The results of the research, based on real case studies, were compared with the documents on water quality in swimming pools in force at the time. An analysis was carried out to determine the relationships between swimming pool water quality before and during the COVID-19 pandemic. The tested parameters determining the quality of water were physico-chemical parameters (temperature, pH, redox, and bacteriological parameters (colony forming units CFU of Pseudomonas aeruginosa, Escherichia coli, Legionella sp.). Based on the results of the analysis of the parameters mentioned-above, the validation of the procedures applied during the COVID-19 hazard and their impact on the quality of swimming pool water were evaluated. The results of the pool water quality tests were discussed with particular emphasis on disinfection by-products (THM and combined chlorine). Detailed analysis showed better water quality in the first year of the pandemic (2020) compared to 2018-2019 (before COVID-19) and 2021 (the second year of COVID-19 pandemic). The following parameters were found to be significantly different: THM (before 0.069 mg/L and during 0.034 mg/L), free chlorine (before 0.86 mg/L and during 0.66 mg/L), and redox potential (before 667 and during 713 mV).

2.
Electronics ; 12(11):2378, 2023.
Article in English | ProQuest Central | ID: covidwho-20244207

ABSTRACT

This paper presents a control system for indoor safety measures using a Faster R-CNN (Region-based Convolutional Neural Network) architecture. The proposed system aims to ensure the safety of occupants in indoor environments by detecting and recognizing potential safety hazards in real time, such as capacity control, social distancing, or mask use. Using deep learning techniques, the system detects these situations to be controlled, notifying the person in charge of the company if any of these are violated. The proposed system was tested in a real teaching environment at Rey Juan Carlos University, using Raspberry Pi 4 as a hardware platform together with an Intel Neural Stick board and a pair of PiCamera RGB (Red Green Blue) cameras to capture images of the environment and a Faster R-CNN architecture to detect and classify objects within the images. To evaluate the performance of the system, a dataset of indoor images was collected and annotated for object detection and classification. The system was trained using this dataset, and its performance was evaluated based on precision, recall, and F1 score. The results show that the proposed system achieved a high level of accuracy in detecting and classifying potential safety hazards in indoor environments. The proposed system includes an efficiently implemented software infrastructure to be launched on a low-cost hardware platform, which is affordable for any company, regardless of size or revenue, and it has the potential to be integrated into existing safety systems in indoor environments such as hospitals, warehouses, and factories, to provide real-time monitoring and alerts for safety hazards. Future work will focus on enhancing the system's robustness and scalability to larger indoor environments with more complex safety hazards.

3.
2022 IEEE 14th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management, HNICEM 2022 ; 2022.
Article in English | Scopus | ID: covidwho-20241015

ABSTRACT

The COVID-19 pandemic has led to a surge of interest in research work involving the development of robotic systems that reduce human-to-human interaction, as such a technology can greatly benefit healthcare industries in preventing the spread of highly infectious diseases. An indoor service robot is built and equipped with wheel odometry and a 2D LiDAR. However, the presence of the systematic odometry errors is evident during field testing. Hence, the possibility of minimizing systematic odometry errors is inspected using various methods of calculation, namely: UMBmark, Lee's and Jung's. The methods all use the Bidirectional Square Path test, performed together with ROS. It is found that Jung's method is the most appropriate method showing a 20.4% improvement compared to the uncalibrated dead reckoning accuracy. Moreover, it is found that the presence of slippage, a nonsystematic error, greatly affects the return position errors of the robot. Consequently, it is recommended to improve the design of the wheelbase to minimize the effects of nonsystematic errors. © 2022 IEEE.

4.
Jurnal Kejuruteraan ; 35(3):567-576, 2023.
Article in English | Web of Science | ID: covidwho-20239915

ABSTRACT

The discovery of the Covid-19 virus in China at the end of 2019 has drastically altered the global landscape. The virus, which has now become a pandemic, has wrought devastation on the world, infecting over 500 million people and killing over 6 million. The virus's mutation into a few variations, however, has enabled the world's alarming situation to continue until now. Airborne particles and viruses including the new Covid-19 variant -Omricon, is not only extremely contagious but also can be transferred by airborne transmission, putting vulnerable people like children at risk, particularly in classrooms. Amongst the strategies to control airborne transmission of viruses and to improve indoor thermal and air quality is using ventilation strategies -such as dynamic insulation. Thus, this paper will review at how dynamic insulation systems in conventional farming and residential buildings, cleanrooms and other controlled environments work to reduce airborne viruses and particles in a room. An innovative "Airhouse" concept that combines with activated carbon has been researched and investigated with regard to the dynamic insulation systems.This system has a high potential to reduce the air temperature, humidity, and airborne viruses including Covid-19 whilst maintaining a steady airflow rate in a normal room. Therefore, it has a great deal of potential to decrease or eliminate concerns about the transmission of airborne viruses and adapt ventilation systems to new pandemic threats.

5.
IEEE Transactions on Knowledge and Data Engineering ; : 1-14, 2023.
Article in English | Scopus | ID: covidwho-20238810

ABSTRACT

Pandemics often cause dramatic losses of human lives and impact our societies in many aspects such as public health, tourism, and economy. To contain the spread of an epidemic like COVID-19, efficient and effective contact tracing is important, especially in indoor venues where the risk of infection is higher. In this work, we formulate and study a novel query called Indoor Contact Query (<sc>ICQ</sc>) over raw, uncertain indoor positioning data that digitalizes people's movements indoors. Given a query object <inline-formula><tex-math notation="LaTeX">$o$</tex-math></inline-formula>, e.g., a person confirmed to be a virus carrier, an <sc>ICQ</sc> analyzes uncertain indoor positioning data to find objects that most likely had close contact with <inline-formula><tex-math notation="LaTeX">$o$</tex-math></inline-formula> for a long period of time. To process <sc>ICQ</sc>, we propose a set of techniques. First, we design an enhanced indoor graph model to organize different types of data necessary for <sc>ICQ</sc>. Second, for indoor moving objects, we devise methods to determine uncertain regions and to derive positioning samples missing in the raw data. Third, we propose a query processing framework with a close contact determination method, a search algorithm, and the acceleration strategies. We conduct extensive experiments on synthetic and real datasets to evaluate our proposals. The results demonstrate the efficiency and effectiveness of our proposals. IEEE

6.
ERS Monograph ; 2022(98):48-58, 2022.
Article in English | EMBASE | ID: covidwho-20238378

ABSTRACT

Air pollution, climate and population health are closely related in terms of their impacts on respiratory health and lung cancer. Air pollutants contribute to the exacerbation of chronic respiratory problems such as COPD and asthma. Air pollutants are also toxic and carcinogenic, initiating and promoting lung cancer development. Climate change in relation to environmental pollution affects the geographical distribution of food supply and diseases such as pneumonia in adults and children. The threat of air pollution, and hence global warming and climate changes, and their effects on population and respiratory health, is an imminent threat to the world and deserves immediate and sustainable combating strategies and efforts. The goals are to increase public awareness and engagement in action, with alignment of international collaboration and policy, and with steering towards further research. Now is the prime time for international collaborative efforts on planning and actions to fight air pollution and climate change before it is too late.Copyright © ERS 2021.

7.
Green Energy and Technology ; : 217-230, 2023.
Article in English | Scopus | ID: covidwho-20238183

ABSTRACT

There is a growing concern about Indoor Environmental Quality (IEQ) in buildings as humans are spending longer in indoor environments, whether this is associated or not with climate change and vulnerability to extreme weather events. In the wake of the COVID pandemic, the need for indoor air quality control is likely to increase, the result of many adaptations in home environments to switch to remote work. In hot countries in the Global South, one of the alternatives is split A/C units with limited air renewal. While, odorless and colorless CO2, commonly generated by occupants through respiration, is among the relevant indoor air pollutants. The purpose of this study is to evaluate a low-cost, responsive air-renewal system in a climate chamber equipped with a standard split A/C unit. The results show the system's feasibility in curbing IAQ concerns and also highlight the risk of negative impacts on indoor thermal conditions and on energy consumption on using A/C. © 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG.

8.
IEEE Internet of Things Journal ; 9(13):11098-11114, 2022.
Article in English | ProQuest Central | ID: covidwho-20236458

ABSTRACT

Recently, as a consequence of the COVID-19 pandemic, dependence on telecommunication for remote learning/working and telemedicine has significantly increased. In this context, preserving high Quality of Service (QoS) and maintaining low-latency communication are of paramount importance. In cellular networks, the incorporation of unmanned aerial vehicles (UAVs) can result in enhanced connectivity for outdoor users due to the high probability of establishing Line of Sight (LoS) links. The UAV's limited battery life and its signal attenuation in indoor areas, however, make it inefficient to manage users' requests in indoor environments. Referred to as the cluster-centric and coded UAV-aided femtocaching (CCUF) framework, the network's coverage in both indoor and outdoor environments increases by considering a two-phase clustering framework for Femto access points (FAPs)' formation and UAVs' deployment. Our first objective is to increase the content diversity. In this context, we propose a coded content placement in a cluster-centric cellular network, which is integrated with the coordinated multipoint (CoMP) approach to mitigate the intercell interference in edge areas. Then, we compute, experimentally, the number of coded contents to be stored in each caching node to increase the cache-hit-ratio, signal-to-interference-plus-noise ratio (SINR), and cache diversity and decrease the users' access delay and cache redundancy for different content popularity profiles. Capitalizing on clustering, our second objective is to assign the best caching node to indoor/outdoor users for managing their requests. In this regard, we define the movement speed of ground users as the decision metric of the transmission scheme for serving outdoor users' requests to avoid frequent handovers between FAPs and increase the battery life of UAVs. Simulation results illustrate that the proposed CCUF implementation increases the cache-hit-ratio, SINR, and cache diversity and decrease the users' access delay, cache redundancy, and UAVs' energy consumption.

9.
IEEE Transactions on Industry Applications ; : 1-7, 2023.
Article in English | Scopus | ID: covidwho-20235410

ABSTRACT

In this paper we report two applications of a subcategory of air cleaning devices based on soft ionization that do not cause molecular fragmentation. A system that includes two unipolar ionizing modules has been used to simultaneously produce positive and negative ions in the air. In one set of experiments a large chamber (28 m3) was used to study the effect of ions on reducing PM1.0 particles produced by a research grade calibrated cigarette. The data presented in this paper were obtained using a carbon-brush-based bipolar ionizer and a MERV 10 filter with electret media in a recirculating HVAC system. Significant improvement in removal rate of fine and ultrafine particles was achieved when using the bipolar ionizer in conjunction with the MERV 10 filter. The second set of experiments were conducted using a 36 m3 chamber, following BSL-3 standards, to study the effect of ions on aerosolized SARS-CoV-2. Results of these investigations reveal the inactivation rate of SARS-CoV-2 are enhanced when ions are introduced in the air;inactivation rates were increased by more than 60%and 90%for ion densities of 10,000/cc and 18,000/cc. IEEE

10.
Acta Polytechnica CTU Proceedings ; 38:138-144, 2022.
Article in English | Scopus | ID: covidwho-20234664

ABSTRACT

Population in developed countries spend most of their time indoors, whether in their homes, workplaces, stores or leisure areas. Due to the COVID-19 pandemic, this situation worsened and now, more than ever, the importance of a high Indoor Environmental Quality (IEQ) is highlighted. The IEQ is very important in building performance since it is directly related to its occupants' comfort, health, wellbeing, and productivity and the Sick Building Syndrome (SBS) concept. Therefore, it is essential to develop tools to support designers' decision-making in the materialization of indoor environments with higher quality. From the state-of-art analysis, it is possible to conclude that the methods to assess the overall building performance already consider the IEQ. Still, most use an approach that does not cover all relevant indicators. In this context, this paper presents the first milestone of a research work that aims to develop a new method to rate the overall IEQ of office buildings in Portugal. The main objective of the present study is to propose a list of IEQ indicators for office buildings, adapted to the Portuguese context, based on the analysis of existing rating methods for buildings and the recommendations of national and international standards. © 2022 The Author(s). Licensed under a CC-BY 4.0 licence.

11.
Buildings ; 13(5), 2023.
Article in English | Web of Science | ID: covidwho-20233959

ABSTRACT

Due to the inherent limitations of underground spaces, such as the lack of natural ventilation and sunlight, underground space users tend to face more health risks compared with their aboveground counterparts. However, little is known about how the underground environment, users' health, and their associations were impacted by the outbreak of the pandemic. In this study, we investigated and compared the impacts of the general underground environment on regular users' physical and psychological health before and after the pandemic. To achieve this aim, the data from 525 surveys were collected from eleven underground sites, followed by an objective field measurement study conducted at five underground sites in Hong Kong pre- and post-outbreak of the pandemic. The multigroup structural equation modelling results indicated that: (i) surprisingly, the users' satisfaction towards almost all underground environment factors, including greenery, connectivity with the aboveground environment, thermal comfort, ventilation, indoor air quality, acoustic comfort, and lighting, excluding wayfinding, were significantly higher in the post-outbreak period;(ii) the users' health, both physical and psychological, was significantly better in the post-outbreak period;(iii) the impacts of visual comfort on the users' physical and psychological health were significantly greater in the post-outbreak period (critical difference ratio (;CDR;) > 1.96);(iv) the impacts of wayfinding, greenery, and acoustic and thermal comfort on the users' physical or psychological health were significant only in the pre-outbreak period (;CDR;> 1.96);(v) the impacts of connectivity on the users' physical and psychological health were significant in both the pre- and post-outbreak periods (;CDR;< 1.96). The findings were further cross-validated using the objective measurement results. With an increasing need to develop healthy underground spaces, the study contributes to the development, design, and management of the underground environment to enhance the users' health in the post-outbreak era.

12.
Engineering, Construction and Architectural Management ; 30(6):2400-2419, 2023.
Article in English | ProQuest Central | ID: covidwho-20231811

ABSTRACT

PurposeThis research presents a comprehensive review of the literature on the barriers to incorporating indoor environmental quality (IEQ) principles into building designs. The aim was to identify these barriers in the literature and subsume them under broad categories for the development of a framework showing the interrelationships among the barriers.Design/methodology/approachThe research design used a systematic desktop review which comprised of three levels of screening. The first level allowed for a broad selection of papers;the second level of screening was done to limit the results to papers within the construction industry, and the third level of screening limited the documents strictly to the publication period of 2000–2021.FindingsTwenty-four (24) barriers were identified in the literature, including lack of integrated design teams, which ranked the highest in appearance, high initial costs, poor market for IEQ buildings and higher design charges among others. The identified barriers were classified into six (6) categories namely capacity barriers, economic barriers, process-related barriers, cultural barriers, client-related barriers and steering barriers.Practical implicationsThe findings of this study would enable practitioners and policymakers to better understand what is preventing the widespread adoption of IEQ designs in the built environment and devise actionable strategies to overcome them. It adds to the body of knowledge on IEQ research by categorizing the various barriers that prevent the delivery of IEQ projects.Social implicationsThe developed barriers in this research can serve as a useful checklist to future researchers who may want to validate the barriers to IEQ designs in empirical studies and in different settings.Originality/valueThe interconnectivity revealed by the web-like framework allows for an appreciation of the various barriers of IEQ adoption which would help in expanding the current knowledge on IEQ beyond the narrow scope of isolated barriers. The fact that the papers selected in this study are not limited geographically, underscores the wide applicability of the findings in the global construction industry.

13.
UCL Open Environ ; 2: e012, 2020.
Article in English | MEDLINE | ID: covidwho-20242311

ABSTRACT

In this study, we first point out the possible acoustic problems associated with the post-pandemic operation of built environments. In particular, we focus on the problem of acoustic deficiency due to the lack of absorption. This deficiency, which is likely to be encountered in most enclosed spaces in a range of establishments, is due to the reduced number of audience members or users of the space as a result of social distancing. As one of the promising solutions to this problem, we introduce a sound absorption technique using three-dimensional (3D) space sound absorbers developed through our recent research projects. Significantly, the type of sound absorber proposed herein is made of materials that are especially suited to hygiene considerations. The materials are microperforated panels (MPPs) and permeable membranes (PMs), both of which are easily washable and sanitised. Furthermore, we point out that 3D-MPP or PM space absorbers possess the additional value of aesthetic designability.

14.
J Am Med Dir Assoc ; 2023 Jun 08.
Article in English | MEDLINE | ID: covidwho-20237531

ABSTRACT

OBJECTIVES: Improving indoor air quality is one potential strategy to reduce the transmission of SARS-CoV-2 in any setting, including nursing homes, where staff and residents have been disproportionately and negatively affected by the COVID-19 pandemic. DESIGN: Single group interrupted time series. SETTING AND PARTICIPANTS: A total of 81 nursing homes in a multifacility corporation in Florida, Georgia, North Carolina, and South Carolina that installed ultraviolet air purification in their existing heating, ventilation, and air conditioning systems between July 27, 2020,k and September 10, 2020. METHODS: We linked data on the date ultraviolet air purification systems were installed with the Nursing Home COVID-19 Public Health File (weekly data reported by nursing homes on the number of residents with COVID-19 and COVID-19 deaths), public data on data on nursing home characteristics, county-level COVID-19 cases/deaths, and outside air temperature. We used an interrupted time series design and ordinary least squares regression to compare trends in weekly COVID-19 cases and deaths before and after installation of ultraviolet air purification systems. We controlled for county-level COVID-19 cases, death, and heat index. RESULTS: Compared with pre-installation, weekly COVID-19 cases per 1000 residents (-1.69; 95% CI, -4.32 to 0.95) and the weekly probability of reporting any COVID-19 case (-0.02; 95% CI, -0.04 to 0.00) declined in the post-installation period. We did not find any difference pre- and post-installation in COVID-19-related mortality (0.00; 95% CI, -0.01 to 0.02). CONCLUSIONS AND IMPLICATIONS: Our findings from this small number of nursing homes in the southern United States demonstrate the potential benefits of air purification in nursing homes on COVID-19 outcomes. Intervening on air quality may have a wide impact without placing significant burden on individuals to modify their behavior. We recommend a stronger, experimental design to estimate the causal effect of installing air purification devices on improving COVID-19 outcomes in nursing homes.

15.
Environ Int ; 177: 108021, 2023 07.
Article in English | MEDLINE | ID: covidwho-20233113

ABSTRACT

Quaternary ammonium compounds (QACs) are a class of surfactants commonly used in disinfecting and cleaning products. Their use has substantially increased during the COVID-19 pandemic leading to increasing human exposure. QACs have been associated with hypersensitivity reactions and an increased risk of asthma. This study introduces the first identification, characterization and semi-quantification of QACs in European indoor dust using ion-mobility high-resolution mass spectrometry (IM-HRMS), including the acquisition of collision cross section values (DTCCSN2) for targeted and suspect QACs. A total of 46 indoor dust samples collected in Belgium were analyzed using target and suspect screening. Targeted QACs (n = 21) were detected with detection frequencies ranging between 4.2 and 100 %, while 15 QACs showed detection frequencies > 90 %. Semi-quantified concentrations of individual QACs showed a maximum of 32.23 µg/g with a median ∑QAC concentration of 13.05 µg/g and allowed the calculation of Estimated Daily Intakes for adults and toddlers. Most abundant QACs matched the patterns reported in indoor dust collected in the United States. Suspect screening allowed the identification of 17 additional QACs. A dialkyl dimethyl ammonium compound with mixed chain lengths (C16:C18) was characterized as a major QAC homologue with a maximum semi-quantified concentration of 24.90 µg/g. The high detection frequencies and structural variabilities observed call for more European studies on potential human exposure to these compounds. For all targeted QACs, drift tube IM-HRMS derived collision cross section values (DTCCSN2) are reported. Reference DTCCSN2 values allowed the characterization of CCS-m/z trendlines for each of the targeted QAC classes. Experimental CCS-m/z ratios of suspect QACs were compared with the CCS-m/z trendlines. The alignment between the two datasets served as an additional confirmation of the assigned suspect QACs. The use of the 4bit multiplexing acquisition mode with consecutive high-resolution demultiplexing confirmed the presence of isomers for two of the suspect QACs.


Subject(s)
COVID-19 , Quaternary Ammonium Compounds , Humans , Quaternary Ammonium Compounds/analysis , Dust , Pandemics , Mass Spectrometry/methods
16.
Building and Environment ; : 110462, 2023.
Article in English | ScienceDirect | ID: covidwho-20231052

ABSTRACT

Indoor airflow patterns and the spreading of respiratory air were studied using the large-eddy simulation (LES) computational fluid dynamics (CFD) approach. A large model room with mixing ventilation was investigated. The model setup was motivated by super-spreading of the SARS-CoV-2 virus with a particular focus on a known choir practice setup where one singer infected all the other choir members. The room was heated with radiators at two opposite walls in the cold winter time. The singers produced further heat generating buoyancy in the room. The Reynolds number of the inflow air jets was set to Re=2750, corresponding to an air-changes-per-hour (ACH) value of approximately 3.5. The CFD solver was first validated after which a thorough grid convergence study was performed for the full numerical model room with heat sources. The simulations were then executed over a time of t=20 min to account for slightly more than one air change timescale for three model cases: (1) full setup with heat sources (radiators+singers) in the winter scenario, (2) setup without radiators in a summer scenario, and (3) theoretical setup without buoyancy (uniform temperature). The main findings of the paper are as follows. First, the buoyant flow structures were noted to be significant. This was observed by comparing cases 1/2 with case 3. Second, the dispersion of the respiratory aerosol concentration, modeled as a passive scalar, was noted to be significantly affected by the buoyant flow structures in cases 1–2. In particular, the aerosol cloud was noted to either span the whole room (cases 1–2) or accumulate in the vicinity of the infected singer (case 3). Turbulence was clearly promoted by the interaction of the upward/downward moving warmer/cooler air currents which significantly affected the dispersion of the respiratory aerosols in the room. The study highlights the benefits of high-resolution, unsteady airflow modeling (e.g. LES) for interior design which may consequently also impact predictions on exposure to potentially infectious respiratory aerosols.

17.
Sci Total Environ ; 892: 164642, 2023 Sep 20.
Article in English | MEDLINE | ID: covidwho-20231300

ABSTRACT

Characterizing the size distribution of airborne particles carrying SARS-CoV-2 virus is essential for understanding and predicting airborne transmission and spreading of COVID-19 disease in hospitals as well as public and home indoor settings. Nonetheless, few data are currently available on virus-laden particle size distribution. Thus, the aim of this study is reporting the total concentrations and size distributions of SARS-CoV-2- genetic material in airborne particles sampled in hospital and home environments. A nanoMOUDI R122 cascade impactor (TSI, USA) was used to collect size-segregated aerosol down to the sub-micron range in home and in three different hospital environments in presence of infected patients in order to provide the concentration of airborne SARS-CoV-2 genetic material for each particle size range at different sampling locations. Providing one of the largest datasets of detailed size-fractionated airborne SARS-CoV-2 RNA to date, we found that 45.2 % of the total sub- and super-micrometric fractions were positive for SARS-CoV-2 with its genetic material being present in 17.7 % of sub-micrometric (0.18-1 µm) and 81.9 % of super-micrometric (>1 µm) fractions. The highest concentration of SARS-CoV-2 genetic material in total suspended particles (5.6 ± 3.4 RNA copies m-3) was detected in the room occupied with patients with more severe COVID-19 symptoms collected during the patients' high flow nasal oxygen therapy. The highest concentration at certain particle size fraction strongly depends on the sampling environment. However, the contribution of SARS-CoV-2 genetic material was in favour of super-micrometric compared to sub-micrometric particle size range. The evaluation of the individual risk of infection was carried out on the basis of the obtained data considering a hypothetical exposure scenario. The obtained results indicate the necessity of the protective masks in presence of infected subjects, especially while staying for longer period of time in the hospital environments.


Subject(s)
COVID-19 , Humans , SARS-CoV-2/genetics , RNA, Viral , Respiratory Aerosols and Droplets , Hospitals
18.
Front Public Health ; 11: 1170085, 2023.
Article in English | MEDLINE | ID: covidwho-20231258

ABSTRACT

Purpose: The study aimed to identify potential risk factors for family transmission and to provide precautionary guidelines for the general public during novel Coronavirus disease 2019 (COVID-19) waves. Methods: A retrospective cohort study with numerous COVID-19 patients recruited was conducted in Shanghai. Epidemiological data including transmission details, demographics, vaccination status, symptoms, comorbidities, antigen test, living environment, residential ventilation, disinfection and medical treatment of each participant were collected and risk factors for family transmission were determined. Results: A total of 2,334 COVID-19 patients participated. Compared with non-cohabitation infected patients, cohabitated ones were younger (p = 0.019), more commonly unvaccinated (p = 0.048) or exposed to infections (p < 0.001), and had higher rates of symptoms (p = 0.003) or shared living room (p < 0.001). Risk factors analysis showed that the 2019-nCov antigen positive (OR = 1.86, 95%CI 1.40-2.48, p < 0.001), symptoms development (OR = 1.86, 95%CI 1.34-2.58, p < 0.001), direct contact exposure (OR = 1.47, 95%CI 1.09-1.96, p = 0.010) were independent risk factors for the cohabitant transmission of COVID-19, and a separate room with a separate toilet could reduce the risk of family transmission (OR = 0.62, 95%CI 0.41-0.92, p = 0.018). Conclusion: Patients showing negative 2019-nCov antigen tests, being asymptomatic, living in a separate room with a separate toilet, or actively avoiding direct contact with cohabitants were at low risk of family transmission, and the study recommended that avoiding direct contact and residential disinfection could reduce the risk of all cohabitants within the same house being infected with COVID-19.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , Quarantine , Retrospective Studies , China/epidemiology , Risk Factors
19.
Build Environ ; 241: 110486, 2023 Aug 01.
Article in English | MEDLINE | ID: covidwho-20230628

ABSTRACT

It is now widely recognised that aerosol transport is major vector for transmission of diseases such as COVID-19, and quantification of aerosol transport in the built environment is critical to risk analysis and management. Understanding the effects of door motion and human movement on the dispersion of virus-laden aerosols under pressure-equilibrium conditions is of great significance to the evaluation of infection risks and development of mitigation strategies. This study uses novel numerical simulation techniques to quantify the impact of these motions upon aerosol transport and provides valuable insights into the wake dynamics of swinging doors and human movement. The results show that the wake flow of an opening swinging door delays aerosol escape, while that of a person walking out entrains aerosol out of the room. Aerosol escape caused by door motion mainly happens during the closing sequence which pushes the aerosols out. Parametric studies show that while an increased door swinging speed or human movement speed can enhance air exchange across the doorway, the cumulative aerosol exchange across the doorway is not clearly affected by the speeds.

20.
Frontiers in Built Environment ; 9, 2023.
Article in English | Web of Science | ID: covidwho-2327634
SELECTION OF CITATIONS
SEARCH DETAIL